Quantity
|
Out of stock
|
||
|
BASIC FEATURES
Recommended boiler volume: 120 - 260 liters
Power of photovoltaic panels: up to 2.7 kWp
Recommended power consumption of the heating element: 2 - 2.5 kW
Network heating backup: YES
Control: touch screen (video)
Production / consumption monitoring: YES
Monitoring history: 10 days
Online monitoring: YES
Use of excess energy: YES - output to the secondary heating element
Recommended power consumption of the secondary heating element: 2 - 2.5 kW
Separate thermostat with secondary heater sensor: YES
Separate thermal fuse with secondary heater sensor: YES
Backup of the secondary heating element by networks: NO
The output to the secondary heating element is active after reaching the "solar" temperature in the primary boiler
TECHNICAL DATA
Input open circuit voltage (limits): 200 - 340 V
Range of the MPP tracker: 185 - 310 V (after reaching the so-called starting voltage from the panels, the MPP tracker "sticks" to the point of maximum power up to approx. 20 V)
Maximum current: 10A
Maximum efficiency: 99%
Thermal fuse: YES electronic
Mains supply: 230V / 5O Hz, fuse 16A
AC and DC fuses and overvoltage protection are integrated in the device, there is no need to install an external switchboard
Protection IP20